Keller Ihne Tesch TRUS/TRH Chamber Furnace
Specifications
Overview
Technical Specifications
- Maximum operating temperature
- 160°C
- Power
- 20.6kW
- Air system
- Recirculating air / fresh air system
- Temperature controller
- Digital PID
- Timer / process control
- Digital
- Recording device
- Digital recording device / chart recorder (TE Direct)
Weight & Dimensions
- Internal dimensions (W x H x D)
- approx. 1000mm x 1500mm x 800mm
- Internal volume
- approx. 1200l
- External dimensions (W x H x D)
- approx. 1600mm x 2100mm x 1200mm
- Total weight
- 580kg
Interested in this machine?
Get in touch with the seller for pricing, additional photos, technical specifications, or to arrange a viewing.
Contact Seller
Know someone who might be interested?
Share this machine with colleagues or friends
Share this machine
AI Description
BetaCapabilities
The Keller Ihne Tesch TRUS/TRH is a reliable industrial chamber furnace designed for controlled heating and drying applications. With a maximum operating temperature of 160°C, 20.6kW power output, and approximately 1,200-liter capacity, this double-door model features a recirculating/fresh air system and digital PID temperature controller for precise, consistent results. The built-in digital timer, process control, and chart recorder (TE Direct) enable detailed monitoring and documentation of heating cycles.
Industries & Uses
Businesses across metal processing, electronics manufacturing, pharmaceuticals, food production, and material testing rely on chamber furnaces for drying components, curing coatings, annealing metals, and quality assurance testing. This model suits mid-sized operations needing reliable batch processing without requiring extreme temperatures.
What to Check When Buying
When evaluating this used furnace, request complete maintenance and service records, particularly for heating element condition and controller performance. Inspect the door seals for wear, verify the chart recorder functions properly, and confirm the recirculating/fresh air system operates without blockages. Ask about calibration history and any temperature consistency issues. A professional inspection is recommended to assess internal heating elements and ensure the digital control systems are accurate and responsive.
This description is AI-generated and is intended as a general guide only. As with all AI-generated content, it may contain inaccuracies. Please verify all details directly with the seller before making a purchasing decision.
Interested in this machine?
Get in touch with the seller for pricing, additional photos, technical specifications, or to arrange a viewing.
Contact Seller
Similar Machines
More machines in Stoves
Know someone who might be interested?
Share this machine with colleagues, partners, or friends who might be looking for similar equipment.